October 2024 Enhancements to NEMreview

Enhancements for Bi-directional Unit Data in the WEM

With bi-directional units making their appearance in WA there comes a need to calculate aggregations for total generation output (+) or total load output (-) of a unit (or group of units).  Previously it was only possible to aggregate the net generation less consumption. To overcome this we have split the “End of Interval Quantity” series into “End of Interval Quantity (Generation)” and “End of Interval Quantity (Load)”.  This follows the similar change we made for NEM units back in April.

End of Interval Quantity (Generation) The output of a unit when generating, otherwise 0MW.  This effectively replaces the “End of Interval Quantity” for generation only units. Previously created Trends and Templates using the “End of Interval Quantity” series will be automatically updated to use this series.

End of Interval Quantity (Load) The output of a unit when loading, otherwise 0MW. The output is given as a positive number to be consistent with existing series for NEM units.

Should one wish to find the net generation of a unit this can be done using a calculation subtracting the EOI(Load) from EOI(Generation) in the Configure step of the editor.

Screenshot showing new columns in the Generators (legacy) tab